Kenmore Upright Freezer 253.21741104 Loss of Power

Over the past 4 years or so, my Kenmore freezer has lost power about 4 times, losing all the food being stored.  All I have to do to "reset" the freezer is to unplug it, wait a few seconds, then plug it back in.  The freezer runs for about 6-9 months reliably, then unpredicably, it will againt shut itself down for some unknown reason and stay off until I discover the situation. Could this be a bad circuit board?  Does this freezer have a circuit board?  Anyone seen this problem and if so, how did you solve it?

Research, Knowledge and Information :


I have a Kenmore Elite upright freezer. After a power outage ...


I have a Kenmore Elite upright freezer. After a power outage the freezer shut off. ... It is model number 253.28099800 and it is actually flashing like this. 0 then ...
Read More At : www.shopyourway.com...

Kenmore freezer model #253.28099800 | Sears PartsDirect


Kenmore freezer model #253 ... 0583 Kenmore Elite FREEZER 0142000 Upright Freezer Kenmore Elite Freezer ... thermistor itself. be sure to disconnect the power first ...
Read More At : www.searspartsdirect.com...

Kenmore 2845 - 13.7 cu. Ft. Upright Freezer Control Manual


View and Download Kenmore 2845 - 13.7 cu. Ft. Upright Freezer control manual online. Electronics Control Guide. 2845 - 13.7 cu. Ft. Upright Freezer Freezer pdf manual ...
Read More At : www.manualslib.com...

Upright freezer stops cooling after power outage or flicker ...


2 Year Old Kenmore Elite After a power flicker or failure, ... Sears Kenmore; Upright freezer stops cooling after power outage or ... OWNER RICK'S APPLIANCE REPAIR
Read More At : www.applianceblog.com...

I have a Sears kenmore elite upright freezer that the alarm


I have a Sears kenmore elite upright freezer that ... this is something due to the power outage,not ... I have not used my 2008 kenmore upright freezer for 3 yrs 6/30 ...
Read More At : www.justanswer.com...

Kenmore 22442 13.8 cu. ft. White Upright Freezer-Sears


Kenmore 22442 Upright Freezer—Stock Up on More FoodThe Kenmore 22442 13.8 cu. ft. Upright Freezer is great for giving you ... Power: Voltage : 115 (V) Capacity ...
Read More At : www.sears.com...

Upright freezer stops cooling after power flickers or outage ...


Discuss Upright freezer stops cooling after power flickers or outage in Refrigerator & Freezer Repair. "Every time the power flickers or goes out for a few minutes ...
Read More At : forum.appliancepartspros.com...

25324092103 KENMORE ELITE FREEZER Manual | Sears PartsDirect


Download Manual for Model 25324092103 KENMORE ELITE FREEZER.Sears PartsDirect has parts, manuals & part diagrams for all types of repair projects
Read More At : www.searspartsdirect.com...

Suggested Questions And Answer :


Kenmore Upright Freezer 253.21741104 Loss of Power


Yes, it does have a control board. It is located under the rear of the freezer near the compressor. There was a service bulletin out a few years ago about the exact problem you are having. I will not be able to find out if your freezer falls under this design change until tomorrow when I get on my computer at the shop. What is happening is the board has a fault in it that won't allow it to come back on sometimes if the power blinks off and back on. I am not sure if the repair credit is still active but we have changed the control boards on many of these units free of charge as recently as a year ago. I will reply back when I find out for sure.
Read More At : Freezer 20.3 cu. ft. Frost Free Upright Freezer...

I have a kenmore upright frost free freezer mod #253.26432100. A couple of months ago everything defrosted and the unit was not running at all. I unplugged it cleaned it and plugged it back in, it turned on and seemed ok. We have been using it since. Last night it did the same thing, everything defrosted and the unit was not running. We cleaned it out, and when I plugged it back in the compressor came on and the unit is running fine. We did not have any loss of power at either scenario. Why is my unit shutting down? Is there some type of overload that only resets when unplugging unit?


You have a problem with the ADC. Frigidaire has also jumped into the market with an adaptive defrost board. The fresh food section light switch and light bulb must work. To initiate a defrost cycle, open the door and push the light switch in and out 5 times within 6 seconds. The compressor and fans should shut off and the defrost heater should come on. Open the door and push the light switch in and out 5 times within 6 seconds to remove the refrigerator from the defrost mode and back into a cooling mode. This product comes equipped with an Adaptive Defrost Control (ADC). To activate manual defrost, press and hold the Freezer temperature UP (WARMER) key while pressing the Fresh Food temperature DOWN (COLDER) key 5 times within 6 seconds. A "d" in the freezer temperature window and "F" in the refrigerator temperature window will display when the heater is activated. To deactivate manual defrost, press and hold Freezer temperature UP (WARMER) key while pressing the Fresh Food temperature DOWN (COLDER) key 5 times within 6 seconds. "d" and "F" will be displayed until the defrost cycle is complete. (approx. 8 minutes)
Read More At : 20.3 cu. ft. / 575 liter Upright Freezer AFFU2068D...

Kenmore freezer quit working after power outage


Simple stuff, you have a compressor a stat and power. check the receptacle to be sure you have 120 volts . then check the compressor with stat at max cold setting to see if you have 120 volts at compressor. if you do then compresssor is bad =new compressor or new unit. if no power to compressor then stat is bad= new stat. i always recomend new unit cause new stat or compressor wont fix a freon leak.... i have replaced a few compressors that died soon after due to a freon leak. good luck...
Read More At : Freezer 20.3 cu. ft. Frost Free Upright Freezer...

Defaults to 0 deg. temp


I would be more worried about constant power disruptions
Read More At : 13.7 cu. ft. / 388 liter Upright Freezer 23424...

Kenmore® (46-26072) Elite® 20.6-Cu. Ft. Frost-Free White Upright Freezer


Check these two things first.  1.  Is there a thick frost buildup on the back panel at the bottom half of the freezer?  2.  Do you hear the fan running inside the freezer?  Let me know what you find.
Read More At : Freezer MQU2057...

Frigidaire frost free upright freezer door corner dripping


Hello Yellow, thank you for your post! I understand that your Frigidaire freezer is dripping water out of the corner of the door. It is possible that with your power going out the heat may have caused the gasket to warp. Do you see any frost build-up? The water that is dripping could be coming from condensation within the freezer. I would recommend checking the gasket to see if it is allowing warm air to enter the freezer. I recommend that you visually inspect the door gasket for defects such as gaps or tears. You can also use a dollar bill to test the door gasket. Place a dollar bill in between the door and the body of the freezer. If the dollar bill pulls out with no to little resistance, you may need to replace the door gasket. A faulty door gasket can allow warm air to enter the compartment and cause frost to condensation or a leak. I hope this information is helpful. -Matt
Read More At : 13.7 cu. ft. / 388 liter Upright Freezer AFFU1466D...

Kenmore Upright Freezer Alarm


Did you ever find out what the problem is? Mine is doing the same thing and I live rurally, there are no repairmen here
Read More At : Freezer 20.3 cu. ft. Frost Free Upright Freezer...

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.
next Question || Previos Question
  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar
all rights reserved to the respective owners || www.glacierfreezer.com || Terms of Use || Contact || Privacy Policy