Guide :Freezers : 14.8 cu. ft. / 419 liter Chest Freezer 13541

Outside surfaces of freezer very hot to touch

I was given a Kenmore chest freezer, it appeared to be functioning properly and was still frozen inside when I took ownership of it. That was a week ago. Today I loaded it with several items, and went out to add another item. The sides and front of the freezer are almost too hot to touch! I can't tell if it is as cold inside as it should be. It's a very basic model with a dial on the side that goes from 1-7 for coldness.

Research, Knowledge and Information :


www.shopyourway.com


www.shopyourway.com
Read More At : www.shopyourway.com...

sides of freezer hot to touch | Sears PartsDirect


sides of freezer hot to touch. ... this is normal for a chest freezer to have areas on the sides of the chest freezer that are very warm.
Read More At : www.searspartsdirect.com...

The outside of my chest freezer feels hot to the touch about


The outside of my chest freezer feels hot to ... The outside of my chest freezer feels hot to the touch about ... This freezer is outside in a garage and has ...
Read More At : www.justanswer.com...

Outside of Upright freezer very hot to touch


Outside of Upright freezer very hot to touch. Get Answers to your Appliance Repair Questions. ApplianceJunk.com. Appliance Repair Forum: Welcome, Guest ...
Read More At : appliancejunk.com...

What Causes a Refrigerator to Be Hot to the Touch? | eHow


What Causes a Refrigerator to Be Hot to the Touch?. ... refrigerator more than normal when outside temperatures are hot and ... My Freezer to Be Too Warm?
Read More At : www.ehow.com...

fridge hot on outside panel - DSLReports Home


Forum discussion: Our side by side fridge/freezer is very hot to the touch on the freezer side outside panel. ... Home Improvement → fridge hot on outside panel.
Read More At : www.dslreports.com...

Freezer Exterior Case Warm - GE Appliances


Freezer Exterior Case Warm. ... (sometimes hot) on the sides. Chest freezers have the condenser wrapped around the outside of the case. The outside white surface is ...
Read More At : products.geappliances.com...

Suggested Questions And Answer :


Outside surfaces of freezer very hot to touch


It should be warm to the touch but not so hot you cant. and also depending on how long the freezer is running and how warm it is where the freezer is will effect how hot the outside is. the reason the outside of the freezer is hot is because thats how the freezer releses its heat from the refrigerant. the longer it runs or the harder it has to work the more heat it has to hive off. so unless the freezer is not cooling there is nothing to worry about.
Read More At : 14.8 cu. ft. / 419 liter Chest Freezer 13541...

The front surface of the chest freezer is pretty hot.


The condenser lines are between the walls of the frzr and if it has a fan to cool the compressor down and it is stalled is the reason the walls are so hot and no it will not cool down over time if new is a flaw in making of this unit take it back or if older only the side should be getting warm not hot then if older be cautious of this no repair can be done on these type of unit they are between foam filled walls....
Read More At : Kenmore...

My freezer does not work all of the time. I HAVE NOTICED that the freezer get very hot at the top of the unit, I have measured this with a digital therm.and temperture was reading 136 degree F. and,the tempertuare probe was not touching anything, just the open air at the top of the unit and in the front, the back was even hotter. You see the freezer is in a cabinet and there are even holes in the side of the unit but,not at the top so,the hot air is forced out at the top right to the front . I even made several 2 inch holes in the back of the cabinet and the unit work for a while but then it stops freezing,we are losing a lot of food. This is a commercial vertical stand up freezer with one glass door.The name brand is true refrigertion in fact the refrigertor that is in a seperate cabinet works just fine. CAN THE FREEZER BE GETTING TO HOT WHICH CAN CAUSE THE UNIT TO SHUT-DOWN AND,IF SO CAN I INSTALL AN EXHAUST FAN IN THE CEILING WHICH IS ONLY AT THE MOST 2 FEET ABOVE THE FREEZER. HOPING TO MOVE THE HOT AIR AWAY FROM THE FREEZER. ANY ADVICE THAT YOU COULD GIVE TO ME WOULD BE IMMENSLEY APPRECIATED. THANK-YOU


The first thing to check is the condenser coil at the bottom of the freezer. Take the slatted front cover off at the bottom where the compressor is located. You will see the conderser coils. This looks like a radiator with aluminum fins, about 16 by 16 inches square. Be sure the coils are clean. Since the compressor is close to the floor it pulls a lot of dust into the coils. You may need to take a long stiff bristle brush to get as much dust as possible off the coils. If this is stopped up, the unit will definately overheat very quickly. While you are down there make sure the fan behind the coils is running. There are several reasons the fan might stop running. The motor can burn out, something can impede the fan blades such as paper, or sometimes rodents. If the fan isn't running the compressor will overheat and shut off. Once you check these basic things, you may then have to address the problem of dissapating the heat. The answer to your question is yes, it will shut down if it gets too hot. You need plenty of air space behind and over the unit in your situation. The air needs to flow into the front bottom section of this unit and flow freely out the back. All commercial refrigeration is designed to operate in 75 degree areas. As your room temperature increases the efficiency of the freezer will decrease. It is not uncommon to find these units in kitchens where the temperature is 85 even 90 degrees. They will continue to work, but will probably run all the time. I would think if you could get 3 to 4 inches of space at the back of the unit and the two feet above the unit with clean coils and properly running fans, you should get better results. You MUST have free flowing air to keep the unit running. The ideal situation is to have the air flow directly through from front to the back of the compressor compartment. In your case, you may have to move the freezer away from the back wall and allow the air to flow up the back of the freezer and out over the top into the room. 2 inch holes are not enough.
Read More At : 23 cu. ft. / 651 liter Commercial Freezer GDM-23F...

Small Frigidaire chest freezer not freezing any longer


Hi, first check the dial inside the freezer and make sure you have it set for a cold temperature, check the back wall or floor of the freezer section for frost, check the freezer (evaporator) fan to see if it is running, check the condenser coil (under the unit) for blockage from dust, check the condenser fan (under the unit) to see if it is running.If you have frost in the freezer, there is a problem with the defrost system and the freezer will start to warm eventually as well as the fresh food section. If that is the problem, you can check the defrost terminator, defrost heater/s, and the defrost timer or adaptive defrost control if used on the unit, or the main control board if so equipped. These things usually require dismantling the freezer and other areas of the refrigerator to be checked.You could defrost the freezer by disconnecting the power to the refrigerator and letting it sit for at least 24 hours with DOORS WIDE OPEN to allow the frost to melt completely but it will build up again in 1-2 weeks and start the warming up again.If the freezer refrigerator is older, then the problem should be with the compressor with either a slow leak of gas or the gas is totally empty. Please call in a repair service.Take care
Read More At : 13 cu. ft. / 368 liter Chest Freezer FFC13C3A...

The front surface of the chest freezer is


Hi, can you put your hands on front of freezer, and check from 1 to 5 without getting burn? how long can you keep your hands on front of freezer? check from 1 to 20 and let me know, normally there's a condensate line, or part of condenser lines that passes through freezer body , purpose of those condensate line is to prevent your door gasket from freezing , especially during winter. It's normal for front of freezer to be warmed, on hot days it will be a little hotter, you said "very hot" makes me wonder how hot it is, put your hands on front of freezer, use number method and let me know, but it's normal. good luck.
Read More At : 5 cu. ft. / 142 liter Chest Freezer 11511...

Freezes for 7 to 14 days then just quits!


Hate to tell you but your compressor is going out on your freezer ,,, i'd look for another freezer.Larry
Read More At : 3.6 cu. ft. / 102 liter Chest Freezer Millenium DCF401W...

Kenmore Chest Freezer


Believe it or not, but it is normal. Especially when just turned on. As the internal temp. gets colder so will the temp. on the side get cooler.
Read More At : 22.7 cu. ft. / 643 liter Chest Freezer 13351...

Kenmore Model # 2539284214 Serial# WB05106301 Found freezer thawing out Compressor was hot and cycling on the Compressor O/L in cycle about 7 times and then started to run Temp inside went to 4.8 Degrees then shut off and came back on at 15.8 degrees It ran like this from 9:30 PM until 5:30 the next day. when i checked it at 5:30 PM it was in the defrost cycle which is suppose to happen after 12 hr.of compressor run time. when it completed the defrost cycle it would start it was cycling on the compressor O/L for about 10 times then it finally started. the amperage on start up was 15.5 then it went to run at 4.5 amps for about 5sec. then tripped out. The cycle time when it was running off the t-stat was approx.30 -40 min. The t-stat is set on #1 and the blower is running Compressor was to hot to touch. My question is the compressor going bad or could it be the door gasket and it is running to long over heating the compressor once it stays running the amperage is 1.5 amps Could it be low on refrigant all the coils are inside. shows no signs of icing up


When its running how hot are the sides the starting amps are too high and 1.5 running amps ain't bad now the the cut in cut out are too high if you look on the dial that the mid point settings that's where you should have it not on 1 1 is hot set it on the straight line that's where you should do all your testing colder settings go up not down you could be overheating the compressor by making it come on too quick the freezer should be about -10 or so do you see any gaps in the gasket
Read More At : 13.7 cu. ft. / 388 liter Upright Freezer 23425...

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.
next Question || Previos Question
  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar
all rights reserved to the respective owners || www.glacierfreezer.com || Terms of Use || Contact || Privacy Policy