Guide :Freezers : 14.1 cu. ft. / 399 liter Upright Freezer 23414

Freezer runs constantly

We have an upright freezer model 253 9239786 mfg 4/95. It runs constantly at 1.7 amps (200 watts) continuously. The sides also feel warm. Does this need service?

Research, Knowledge and Information :


Why does my upright freezer run constantly?... | Sears ...


Barbara H. , January 05, 2013 we all worry about electric costs, so i understand the concern about a freezer that continually runs.
Read More At : www.searspartsdirect.com...

Refrigerator Runs Constantly - Repair Parts - RepairClinic.com


Refrigerator runs constantly? ... As a result, it will run constantly. The freezer temperature should be set between 0 and 5 degrees Fahrenheit (-18 to -15C).
Read More At : www.repairclinic.com...

How To Fix Refrigerator That's Running Too Long | Fridge Repair


Find out how to repair a refrigerator that's running too long by troubleshooting common problems and parts ... The fresh food and freezer compartment temperatures ...
Read More At : www.partselect.com...

Freezer Troubleshooting – What to Check Before You Call a Pro ...


Freezer Troubleshooting – What to Check Before You Call a Pro. by Chris Jones. ... Freezer Runs Constantly. If your freezer runs far more than you expect, ...
Read More At : www.realestate.com...

Refrigerator Condenser Fan Is Always Running - SF Gate


Refrigerator Condenser Fan Is Always ... (and freezer if you ... This is usually some form of rubber-based seal which runs the perimeter of the door to keep the ...
Read More At : homeguides.sfgate.com...

Kenmore Freezer Runs All The Time - Model 253.26432100 ...


Kenmore freezer runs all the time - model #253.26432100? Use our DIY troubleshooting & videos. Then, get the parts you need fast. Return any part for 365 days.
Read More At : www.repairclinic.com...

5 Common Freezer Problems – APWagner Appliance Parts Blog


May 21, 2008 · Question 1: Why doesn't the freezer work at all? Answer 1: Are you sure that the freezer is getting power? If you can’t tell if anything is on at all ...
Read More At : apwagner.wordpress.com...

Refrigerator compressor is running and is not cold or cooling ...


If one dial is in the freezer section and one is in the food ... it is running constantly to time your defrost ... the icemaker motor runs whenever the compressor is ...
Read More At : www.appliancerepair.net...

My refrigerator runs constantly | Amana Owner Center


If your refrigerator runs constantly, follow this checklist to help learn why and what you can do to make sure your refrigerator is working properly.
Read More At : owners.amana.com...

Troubleshooting a Refrigerator That Runs Continuously ...


Troubleshooting a refrigerator that runs continuously requires an understanding of how the refrigerator works.
Read More At : www.doityourself.com...

Suggested Questions And Answer :


Freezer is constantly running and sides seem to be caving in on outside


Most likely there is a defect in the coolant system, you might want to get a repair man to help. What i think is happening is water is getting in the sides and when it expands/ contracts it causes the sides to cave in.
Read More At : 20 cu. ft. / 566 liter Upright Freezer FFU20FC4A...

Freezer Not Working


The most likely answer is a slow freon leak assuming it was getting to the right temperature before you went on vacation.
Read More At : 13.7 cu. ft. / 388 liter Upright Freezer 23424...

Defaults to 0 deg. temp


I would be more worried about constant power disruptions
Read More At : 13.7 cu. ft. / 388 liter Upright Freezer 23424...

I recently bought a 20.5 cu.ft Haier upright freezer. Frost is forming at the top near the light on/off switch and the freezer constantly runs. It has not shut off in the three weeks since I purchased it. My question is, should it constantly run?


No sounds like the door is not sealing
Read More At : 20.5 cu. ft. / 580 liter Upright Freezer HUF138PA...

Kenmore Upright Freezer compressor running 6 seconds every minute


Usually the compressor runs pretty warm anyway. However if you think it's too hot I would start with the condenser coils located either under the unit or on occasion they are located on the back. The air flow across these coils as well as the airflow around the compressor must be maintained. I forgot to ask if the condenser fan is running. Check and make sure that the Fan is running and the air flow is good. Also, When you transported the unit did you move it standing vertically like it normally stands or did you lay it on its side. If you transported the unit on its side you must wait a minimum of 24 to 48 hours prior to start up or the unit could be ruined permanently. The refrigerant has to be utilized through the compressor as a gas. If the unit is on its side liquid refrigerant could be introduced into the compressor and can cause permanent damage. If this is the case I recommend that you turn the unit off at once and wait the 36 hours for the Refrigerant to settle then try it again. This transportation rule applies for any appliance That uses refrigerant, Air Conditioners etc. These units are not that hard to diagnose. The only other item that is usually a problem is the defrost timer. It is not very expensive and can also cause some of the same symptoms that you are eluding to. The defrost timer allows the freezer to periodically shut down to prevent the buildup of frost or ice on he evaporator coils and on the inside the unit. If it is defective, then the unit will either run all the time and cause the evaporator coils to freeze up or will not allow the compressor to switch on and it will not freeze like it should.
Read More At : 13.7 cu. ft. / 388 liter Upright Freezer 23429...

Kenmore upright freezer


1)forget about the key you'll be disposing of this unit anyway 2)the alarm is to tell you that the unit is above ideal temp. 3)the unit isn't making temp due to refrigeration issue. if it isn't cold enough on 3 then 1 won't do it either.
Read More At : 20.3 cu. ft. / 575 liter Upright Freezer 23024...

Freezer is running constantly and sides and top are hot.


First whirlpool makes a good product as far as the sides being hot good sign the condensing coils are in the sides are supposed to be hot worry if its running and they are cold then not working right ok as far as running modern units useing 134a do have long run times but are not using but same enegry as 100watt light bulb otay
Read More At : 14.1 cu. ft. / 399 liter Upright Freezer 23414...

Kenmore Upright Freezer Alarm


Did you ever find out what the problem is? Mine is doing the same thing and I live rurally, there are no repairmen here
Read More At : Freezer 20.3 cu. ft. Frost Free Upright Freezer...

Freezer runs constantly


Not necessarily, is it maintaining temp? all food staying frozen? especially ice creams if stored in there. most newer freezers displace the heat generated while cooling the food through copper lines running through sides of unit, helps to cut down on air temp differences between the inside (0 degrees) and outside temp to prevent moisture and possible condensation causing premature rusting of unit
Read More At : 14.1 cu. ft. / 399 liter Upright Freezer 23414...

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.
next Question || Previos Question
  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar
all rights reserved to the respective owners || www.glacierfreezer.com || Terms of Use || Contact || Privacy Policy
Load time: 0.0731 seconds