Guide :Freezers : Freezers

Taylor 430-12 low pressure adjustment for frozen cocktails

What is the correct setting for the low side with expansion valve to make cocktails with this machine.

Research, Knowledge and Information :


Taylor Company


Offer super premium frozen custard, low overrun ice cream or sorbet in three ... exotic frozen cocktails and non-alcoholic ... Model 430. Frozen Beverage ...
Read More At : www.taylor-company.com...

Frozen Drink & Slush Machines - Professional Equipment


Taylor Model 340-12 Frozen Drink Machine $1599.00 Taylor 340-12 Margarita ... more cocktails, frozen ... REFRIGERANT 404A 66 OZ DESIGN PRESSURE HIGH 500. LOW ...
Read More At : professionalequipmentlistings.com...

Torrents – Torrent Sites and Search


Search torrents on dozens of torrent sites and torrent trackers. Unblock torrent sites by proxy. PirateBay proxies, RARBG unblocked and more torrent proxies.
Read More At : torrents.me...

HOW-TO: John Deere L100 Lawn 42" Tractor/Mower Brake ...


Update 4/11/2015 --Wow. Six years after I wrote the original post and it's still helping people! I love your feedback this time of year and I read every single one.
Read More At : www.thenorth.com...

Roy J. Dossat - Principles Of Refrigeration.pdf | Pressure ...


Roy J. Dossat - Principles Of Refrigeration.pdf ... intensity or thermal pressure, is Likewise, a low temperature ... pressure 2-12.
Read More At : www.scribd.com...

Jp101714 low by JewishPress.com - issuu


Title: Jp101714 low, Author ... , 12 All of Israel reads publicly from the Torah the ... Why introduce more adjustment problems?” “Making aliyah with ...
Read More At : issuu.com...

Vintage Vinyl:Steal This Book - Sophia Smith


Steal This Book is, ... and the like are readily available jobs with such high turnover and low pay that little checking ... Colorado State Free U-Box 12 ...
Read More At : sophia.smith.edu...

Tw 11 12 14 by The World Newspaper - issuu


Title: Tw 11 12 14, Author: The World ... with its typically low crime rate, ... Coos Bay. Barbara Taylor and Eric Clough of Cape Arago Audubon will share ...
Read More At : issuu.com...

Omaha World-Herald - Official Site


Online version of the largest daily newspaper in Nebraska with local, regional, national and international news, weather, and sports and features.
Read More At : www.omaha.com...

Suggested Questions And Answer :


Our dial for the 12.5 cubic freezer is 0-7 the book says it is set at the factory but you can adjust what is an average number to have the dial at as we are not always at the cottage to moniter it I have it to cold right now and do not want to turn it to low and my manuel does not tell you the factory setting\r\n thanks


The average number to have it set at is 4.to 5. I would start on 5 and if it is to cold then turn it to 4. That is where I would start.
Read More At : 12 cu. ft. / 340 liter Upright Freezer FFU12C2A...

This unit has a crank case pressure regulator and it is icing up I am unsure of the correct charge becauase the data plate is gone; however I did adjust the cpr valve to where i had a svt of -20 and this is an r-22 unit. This unit has a new t-stat and the problem is that it wont get colder than 0 or 10 degrees. Then the temp rose to 20 and thats when the product was removed and unit was shut off. What do you think? I may try and charge by superheat but i am unsure of the general amount. This has a cap tube metering device so i do not want to overcharge it.


Freezers usually have a super heat of 6-8 degrees and as it approaches the set temperature, it can be as low as 4 degrees. you will have to 'babysit' this and adjust as you go but it has to be done in extremely small amounts. the crankcase pressure regulator basically keeps the compressor from being overloaded from high pressure like from after a defrost or the door being left open.
Read More At : Commercial Freezer DCCG-12...

Ffu20fc6aw4 Freezer runs too much. Located in garage. Runs almost non-stop in summer; 0 degF here & still cycles often. Defrost coil does not ice up, defrost element OK, defrost tstat will open & close. Have replace freezer tstat. Seems like it could be the defrost timer stuck in ON position, causing unit to defrost every time defrost tstat closes. Food stays frozen & temp stays around 0 deg F in freezer. Is it logical defrost timer could be the problem.


How old is your model you have. a weak pump will make the system slower to get to temp even a broken seal can do this. even just a few mil gap can make it do this. if you close the door then re-open it it should be harder to open the door. this is the seal being nice and tight to its fittings.
Read More At : Freezers...

How do i get my Kenmore Elite freezer out of demo mode


Which model freezer do you have? A few possible resets: press and hold the Set and + keys for 5+ seconds. On some models, that will get the freezer out of demo mode. On other models, it's the Set and Down arrow. For a few models, it's the Options and Up arrow. In all cases, it's press and hold both buttons until the unit responds. I hope you will add a comment with the model of your freezer so that I can determine which set of instructions will work for your unit. Cindy Wells
Read More At : Kenmore...

Freezer alarm beep can't reset showing CE then -10/CE 0 food ok


Thanks for your question!I'm sorry that you haven't received an answer yet.The response rate on FixYa FREE questions is usually over 80%, but sometimes questions go un-answered when:1. the question is unclear, incomplete, or poorly worded...2. the question is mis-categorized - so the correct experts aren't viewing it...3. the question requires an answer for something that cannot be explained online adequately...4. specific training, tools, or equipment are required to avoid injury or death...5. the Experts that are online simply don't have the resources to answer your question fully...Please feel free to re-work your question if you feel one of these may be the reason.Of course you are not required - but converting your question to a PAID one usually increases the reply rate as well.Normal rates for FixYa are...$ 9.99 answer for one question.$12.99 Live Real-Time online chat or premium e-mail support.$29.99 Live Real Time phone supportSometimes FixYa will run specials for unlimited questions via monthly subscription or reduced rates for limited periods.Consider the savings that can be had when an informed Expert can save you a $100 service call, or a $350 trip to the car dealership.Your problem solved - guaranteed! Or your money back!!If you don't want to pay - feel free to re-submit your question so it returns back to the top of the work queue if you still need help.Thanks for using FixYa - a 4 THUMBS rating is appreciated for helping with your FREE question
Read More At : 20.6 cu. ft. / 583 liter Upright Freezer FFU2124D...

The fridge is working in low level (the controler know is between 0 and 1 stage)with a temperature +2 celcius and at the same time the freezer's temperature is -12 degrees celcius. If i try to move the freezer' temperature to a lower position by getting the knob to a higher lever, then the fresh food dept temperature is in minus level (below 0 degrees celcius. Could you please help me?


Kindly check the following Wiring Thermostat Defrost timer Compressor If you can hear some sound of a fan then the compressor is working..As for the other devices you have check for open circuits. You may need an assistance from a repair person.Check also this link and it might help:http://apwagner.wordpress.com/2008/05/22/5-common-freezer-problems/Hope it helps and have a great day!
Read More At : Maytag...

Icemaker makes shells. Outside is frozen but


Hollow cubes are caused by not having enough water in the ice mold. Fill it up manually by pouring water in it and see how the cubes turn out. look for an adjustment behind the plastic endcover with a +/- on it. - is less water. + is more water. Try swapping the wires on the dual water inlet valve. Then try the water dispenser. The water should go to the ice maker. This will tell you weather or not the ice maker valve is working and if the line is clear.There is a screen filter before the water inlet valve in the water line. It can get partially stopped up with sediment blocking water flow.
Read More At : Freezers...

Traulsen G sereis 2 door freezer keeps running past set temp of "0" degrees keeps freezing all the way to -35 degrees and I have to shut it off to keep it from running? any advice??


It basically sounds like the temp sensor is not sensing the box temp that the control functions on. Other wise, the control may be stuck. Traulsen seems to have a fairly descent tech support line. Call them for steps on how to read the controller.
Read More At : G-Series G22000 Solid Door 2-Section Freezer...

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.
next Question || Previos Question
  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar
all rights reserved to the respective owners || www.glacierfreezer.com || Terms of Use || Contact || Privacy Policy
Load time: 0.0614 seconds